Rafter spans for southern yellow pine douglas fir and eastern spruce.
Roof rafter span tables australia.
1 refer to general notes for information that is relevant for all span tables.
Our experienced support team can assist with enquiries ranging from beam sizing to installation advice.
Tables such as those for rafters floor joists and ceiling joists require the spacing of members to be known.
For simple construction such as domestic construction this can be determined from span table supplements in as1684 2 and as1684 3.
Loads are calculated in accordance with table 3 1 of as nzs 1170 1 2002.
Joists crippled over supports shall be considered as single span joists.
Rafter span tables use these tables to determine lengths sizes and spacing of rafters based on a variety of factors such as species load grade spacing and pitch.
Table assumes a maximum flooring mass of 40kg m2.
Visit the roof framing page for more information on cutting roof rafters and visit the roof pitch calculator for determining rafter lengths based on rise and run.
This is set by the roof use you selected in the previous screen and cannot be modified.
Step 4 assume the wind classification for the area is n1 and the roofing profile is stramit corrugated cladding 0 48mm bmt thickness in a single span configuration.
Flat roof span tables allow for a maximum roof pitch of 5ยบ.
Span tables allow users to choose an appropriate size and stress grade to achieve spanning needs.
A maximum roof pitch of 25 degrees is assumed.
Pergola rafter spans for 600 mm and 900 mm spacing.
Stress grades and timber sizes combine to determine the spanning ability of load carrying members.
Rafter or uss spacing w lintel span sheet roofing tiled roofing roof load width rlw mm.
Reading off the empty under table with h 5m hc 2 5m span table c will be used to determine the spans.
The imposed uniformly distributed live load in the main span.
Roof beams 20 verandah beams 22 garage roof.
Can t find what you are looking for.
Wind classification n1 n2.
If you are looking for span tables design guides install guides product catalogues or safety data sheets then you ve landed on the right page.
Maximum span of lintel mm tile roof 240 x 35 2600 2100 1000.
Pitching beams 23.
2 for design parameters refer to figure 7 26.
Or selected in order to obtain the.
Spantec has prepared these tables for use by people skilled in the design and specification of the type of.
Use the single span tables for the purpose of obtaining the appropriate size.
Technical diagram span tables f7 rafters on page 35 30mm m aximum allow able sp ans mm sheet roof spacing mm rafter size 600 760 900 1000 1200 66 x 30 1250 1150 1050 1000 950 90 x 30 1650 1550 1550 1400 1300 138 x 30 2600 2300 2150 2000 1800 185 x 30 3000 2650 2450 2350 2150 230 x 30 3050.
Use recommended minimum roof pitches as specified by roof sheet supplier.